betti cad check
Find what is wrong with a STEP file: gaps, open shells, faces turned over, short edges.
cad module Granted on request: see access and licensing.
Usage
betti cad check [flags] in.step
Examples
betti cad check part.step
betti cad check -tol 0.01 part.step
betti cad check -json part.step > defects.json
Flags
| Flag | Takes | Default | Meaning |
|---|---|---|---|
| -small | number | none | length below which edges are short, in mm (0: a ten-thousandth of the model's size) |
| -tol | number | none | least tolerance to judge gaps by, in mm, whatever the file states (0: 1e-07) |
Output flags
| Flag | Takes | Default | Meaning |
|---|---|---|---|
| -json | switch | off | print the result as JSON |
| -q | switch | off | print nothing but errors |
| -v | switch | off | also show the stages of each step, and their times |
This page is generated from betti help cad check. Lengths are absolute, or a percentage of the part's bounding-box diagonal, as in -size 1%.